Range switch position | D-value | Opacity % | Mass scale in mg/m3on 1 m distance | Mass scale in mg/m3 on 2,5 m distance | Mass scale in mg/m3 on 5 m distance |
1 | 0...0.03 | 0...6.7 | 0...24 | 0...9,6 | 0...4,8 |
2 | 0...0.1 | 0...20 | 0...80 | 0...32 | 0...16 |
3 | 0...0.3 | 0...50 | 0...240 | 0...96 | 0...48 |
4 | 0...1.0 | 0...90 | 0...800 | 0...320 | 0...160 |
Option: | 0...3.0 | 0...99 | 0...2400 | 0...960 | 0...480 |
Mass scale values are evaluated using the following parameters: particle size of avg. 1 μm and particle density 1 kg/dm3
Standard delivery doesn’t include blower1, electricity cables2 and audit filters3.
TARGETED PURGE AIR FLOW FOR LENS MAINTENANCEPurge air is used to keep the lens clean through creating a buffer between the lens and the stack gases. For the situations where enhanced cleaning is needed, we offer a special flange that guides the air purge to the lens. This construction is easy to disassemble and clean when necessary. It is made of anodized aluminum. |
![]() |
100 MM LENSFor longer measuring paths we offer the receiver with a 100 mm lens. The possible measuring path is dependent on stability of the transmitter. However, the realistic measuring path for the standard receiver is up to 5 m. With this option it’s possible to have longer measuring paths. This option is also useful in places where high level vibration presents or on in other way unstable installation site. This receiver can be used to minimize outage time by improving the monitor’s availability. Standard flange is ANSI 4”. This option includes targeted purge air flow to keep lens clean. |
![]() |
INTEGRATED SUN AND RAIN COVER WITH ADAPTER FLANGESIn some installations an adapter is needed between dust monitor’s flange and the existing one in the stack. We offer more developed adapter flange which has integrated sun and rain cover. DN50 (only for transmitter), DN65 and ANSI4” are supported. Material options are: stainless steel and anodized aluminum for the flange, stainless steel for the cover. |
![]() |